Freescale Semiconductor /MK21F12 /ADC0 /SC3

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as SC3

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (00)AVGS 0 (0)AVGE 0 (0)ADCO 0 (0)CALF 0 (CAL)CAL

CALF=0, AVGS=00, ADCO=0, AVGE=0

Description

Status and Control Register 3

Fields

AVGS

Hardware Average Select

0 (00): 4 samples averaged.

1 (01): 8 samples averaged.

2 (10): 16 samples averaged.

3 (11): 32 samples averaged.

AVGE

Hardware Average Enable

0 (0): Hardware average function disabled.

1 (1): Hardware average function enabled.

ADCO

Continuous Conversion Enable

0 (0): One conversion or one set of conversions if the hardware average function is enabled, that is, AVGE=1, after initiating a conversion.

1 (1): Continuous conversions or sets of conversions if the hardware average function is enabled, that is, AVGE=1, after initiating a conversion.

CALF

Calibration Failed Flag

0 (0): Calibration completed normally.

1 (1): Calibration failed. ADC accuracy specifications are not guaranteed.

CAL

Calibration

Links

() ()